PureBytes Links
Trading Reference Links
|
The following is the procedure if you run into problem installing under
Win2000:
-----------------------------------------
>Mr. Berentson,
>
>The only issue encountered to date between the products has been related to
>the Security Block drivers. In order for the block to be recognized, the
>steps outlined in the Ntreadme.wri file located in the
>Omega\Prog\Drivers\NT
>directory must be completed. The text of this file is included below. In
>addition, the following lines must be added to the system.ini file as the
>first two lines under the [386Enh] Section as follows:
>[386Enh]
>device=ssiact.386
>SSI_LPT=1
>1 is used for LPT1, 2 for LPT2, etc. if the block is attached to a port
>other than LPT1.
>Text of Ntreadme.wri file:
>NOTE: Using Windows 2000, the System32 directory is located in the Windows
>directory, not WINNT as outlined below. Please use the Windows\SYSTEM32 or
>Windows\SYSTEM32\DRIVERS\ directory where applicable. Manual Installation
>of the Security Block under Windows NT The following is a list of
>instruction on how to manually install the drivers for the Security Block
>under the Windows NT operating system:
>Step 1
>Copy the following files located in your OMEGA\PROG\DRIVERS\NT directory to
>the WINNT\SYSTEM32\DRIVERS\ directory:
>SSIDDDP.SYS
>SSIPDDP.SYS
>Step 2
>Copy the following file located in your OMEGA\PROG\DRIVERS\NT directory to
>the WINNT\SYSTEM32\ directory:
>SSIVDDP.DLL
>Step 3
>Add the following line to the CONFIG.NT file in Windows NT WINNT\SYSTEM32
>directory.
>DEVICE=%SystemRoot%\system32\drivers\SSIDDDP.SYS Step 4 Locate your MS-DOS
>prompt. At the prompt type the letter of the drive in which your Omega
>directory resides followed by the colon and the pressing Enter or Return
>key.
>Then Type in the following line followed by pressing the Enter or Return
>key.
>CD\OMEGA\PROG\DRIVERS\NT\SSIREGI install
>If you are installing your Security Block on LPT1, STOP HERE and restart
>your computer. You have completed the installation of the Security Block.
>If
>you are installing the Security Block on another LPT port continue with the
>remaining steps.
>Step 5
>Locate your MS-DOS prompt. At the prompt type the letter of the drive in
>which your Omega directory resides followed by the colon and the pressing
>Enter or Return key.
>Then Type in the following line followed by pressing the Enter or Return
>key.
>CD\OMEGA\PROG\DRIVERS\NT\SSIREGM LPTPort=n (n, representing the number
>assigned to your parallel port) You have completed the installation of the
>Security Block.
>***************************************************************************
*
>***********************
>Upgrading to TradeStation Version 4.0
>When you are upgrading from a previous version of TradeStation to the
>current build and you get the message 'SSIACT.386 not loaded' after
>rebooting, you will need to perform these steps:
>1. Locate the Control Panel. (This can be found under the program group
>MAIN in Windows NT 3.5X or START - SETTINGS in Windows NT 4.0)
>2. Double click the Devices.
>3. Find the Device name "SSIPDDP: Parallel port device driver," then
>click on the listing to highlight it.
>4. Click on the Startup... button.
>5. Select the Disabled radio button and click OK.
>6. You will now need to reboot your computer.
>Once you have restarted Windows NT, you will be prompted that the SSIVDDP -
>SSIPDDP driver has not been loaded. Please disregard this message and
>proceed with the installation of TradeStation 4.0. Once the installation is
>complete, Setup will ask you if you would like to restart the computer.
>Click NO. You will need to enable the device SSIPDDP. Perform the following
>steps to ensure proper installation:
>1. Locate the Control Panel. (This can be found under the program group
>MAIN in Windows NT 3.5X or START - SETTINGS in Windows NT 4.0)
>2. Double click the Devices.
>3. Find the Device named "SSIPDDP: Parallel port device driver," then
>click on the listing to highlight it.
>4. Click on the Startup... button.
>5. Select the Automatic radio button and click OK.
>6. You will now need to restart the computer.
>THE INSTALLATION IS NOW COMPLETE.
>If you have any further questions or concerns, please feel free to contact
>us. Thank you for your continued support.
>Sami Kutbi
>2000i Software Support Department
>
>TradeStation Technologies, Inc.
>(Formerly Omega Research, Inc.)
>A wholly owned subsidiary of
>TradeStation Group, Inc. (Nasdaq: TRAD)
-----Original Message-----
From: kjh129 [mailto:kjh129@xxxxxxxxxxx]
Sent: Wednesday, March 14, 2001 7:54 AM
To: omega-list@xxxxxxxxxx
Subject: SSIACT.386 NOT LOADING
Hi Folks,
Upgraded to W2K. When reinstalling TS4.0 with the upgraded builds on
this OS, i am getting the message "SSIACT.386 NOT LOADED". Has anyone
running w2k run into this problem? If so, what was your solution? I
downloaded the supposed lastest one from omega's website and used that one,
no resolution using that. Nothing in the faq's or their knowledge base seems
to pertain to this problem. Thanks in advance,
KJH
|