[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

RE: Sad days for data for TS4 traders



PureBytes Links

Trading Reference Links

Ron, there I a multiplier allowed in the driver for the IO card that gets
around the problem. So when you set your GS to 115kb and use a multiplier of
2 or 4 and your resulting baud should be 230k or 460k respectively.

Attila


-----Original Message-----
From: ron@xxxxxxxxx [mailto:ron@xxxxxxxxx]
Sent: Tuesday, January 18, 2000 2:32 PM
To: attila_antal@xxxxxxx; Omega-List
Subject: RE: Sad days for data for TS4 traders


The Omega Server does not support a baud setting higher than 19.2 when
talking to a Signal Sat box.

Ron

-----Original Message-----
From: attila_antal@xxxxxxx [mailto:attila_antal@xxxxxxx]
Sent: Tuesday, January 18, 2000 10:01
To: Omega-List
Subject: RE: Sad days for data for TS4 traders


Pierre, are you saying that the limit of 19.2 comes from DBC bandwidth
or
the software interface does not have a setting above 19.2kb? Please
realize
that I don't use BMI or TS4 anymore, just trying to be helpful.

Attila


-----Original Message-----
From: pierre.orphelin@xxxxxxxxxx [mailto:pierre.orphelin@xxxxxxxxxx]
Sent: Monday, January 17, 2000 4:38 PM
To: Attila Antal; Omega-List
Subject: Re: Sad days for data for TS4 traders



----- Message d'origine -----
De : Attila Antal <attila_antal@xxxxxxx>
À : Omega-List <omega-list@xxxxxxxxxx>; Ron Dawes <ron@xxxxxxxxx>
Envoyé : lundi 17 janvier 2000 21:11
Objet : RE: Sad days for data for TS4 traders


> Guys, there is a lot of us use DTN Sat where the IO port speed is an
issue.
> TurboExpress card will handle speeds up to 460kb and it comes with its
own
> driver. This driver is able to multiply settings in Omega to 4 times
so
your
> 115kb becomes 460kb.
>
> Hope this helps.
>
> Attila
>

It does not help.

Dynastore emulates the DBC server abdis tied to the original DBC Omega
interface, itself limited to
19.2 kb.
This means that I was rightin aprevious discussion whentelling that
these
converters are nothing else than DBC datafeed translators.
Theytraslate the symbols into DBC format and TS4 accepts them as DBC
format,
LIMITED to 19.2 kb, or to whatever DBC speed limitation may exist by
construction ofthe DBC Omega interface.

You may add a zillionbyte hitech serial port card ,the Omega DBC
interface
only understand : it's a 19.2kb DBC feed.

Sincerely,

-Pierre Orphelin
Neurofuzzy Logic tools for TradeStation
Free evaluation versions and competitive upgrades available
web: http://www.sirtrade.com