[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: Ton Maas Slander



PureBytes Links

Trading Reference Links

Because of all the slander I have receive from Ton Maas I will no longer be
sending out my program.  Which was a FREE program to help new Metastock
users get up and running with real data. Some people on this list feel that
if you aren't giving away formulas or trades then your not contributing to
the list. There are many ways to help other Metastock users besides just
giving help with formulas.  It's just too bad that one or two people have to
ruin it for the majority.

I apologize to all the traders that would have liked to use my program.
You're free to send Ton Maas a note expressing your feelings on this
subject.  I, along with many others, have given up!!

Don LaBarre
Web Developer
Visual Basic Programmer
www.u2ecom.com
www.cedarcreektrading.com
www.auto607.com
www.conklinplayers.com

----- Original Message -----
From: "Guy Tann" <grt@xxxxxxxxxxxx>
To: "Metastock User Group" <metastock-list@xxxxxxxxxxxxx>
Sent: Sunday, October 01, 2000 3:41 AM
Subject: calculations


> Don,
>
> Here's part of what I had in one indicator that I called COMHX01X09.
>
> COMHX03:= ( FmlVar("COMH-MXX","COMHMXX") - Ref(
> FmlVar("COMH-MXX","COMHMXX") , -3 )) / 3;
>
> COMHX04:= ( FmlVar("COMH-MXX","COMHMXX") - Ref(
> FmlVar("COMH-MXX","COMHMXX") , -4 )) / 4;
>
> COMHX05:= ( FmlVar("COMH-MXX","COMHMXX") - Ref(
> FmlVar("COMH-MXX","COMHMXX") , -5 )) / 5;
>
> COMHX06:= ( FmlVar("COMH-MXX","COMHMXX") - Ref(
> FmlVar("COMH-MXX","COMHMXX") , -6 ) ) / 6;
>
> COMHX07:= ( FmlVar("COMH-MXX","COMHMXX") - Ref(
> FmlVar("COMH-MXX","COMHMXX") , -7 ) ) / 7;
>
> COMHX08:= ( FmlVar("COMH-MXX","COMHMXX") - Ref(
> FmlVar("COMH-MXX","COMHMXX") , -8 ) ) / 8;
>
> COMHX09:= ( FmlVar("COMH-MXX","COMHMXX") - Ref(
> FmlVar("COMH-MXX","COMHMXX") , -9 ) ) / 9;
> COMHX09;
>
> The only thing missing is COMHX01 and COMHX02.  When running, it works
> sporadically or not at all.  I cut and pasted COMHX01 and COMHX02 into
their
> own indicators (which is how I tested them in the first place) and they
work
> fine.  I'm now moving all of these back into individual indicators.  I
have
> no idea why this didn't work since I only had 9 variables.  The COMX09;
> entry was strictly for plotting purposes so I could check out the detailed
> results (remember, I'm doing a conversion here and need to verify
> calculations to 4 decimal places).
>
> After verifying my calculation results, I delete the final COMHX09
plotting
> entry.  Anyway, why they don't work when contained in one indicator and do
> work when cut and pasted into their own indicator, I have absolutely no
> idea.
>
> Regards,
>
> Guy
>